Skip to main content
Publications | Persons | Institutes | Projects
[ report an error in this record ]basket (0): add | show Print this page

Determination of volatile organic compounds in marine biota
Roose, P.; Brinkman, U.A.Th. (2005). Determination of volatile organic compounds in marine biota, in: Roose, P. Volatile organic compounds and related microcontaminants in the Scheldt estuary and the southern North Sea: method development and monitoring. pp. 85-108
In: Roose, P. (2005). Volatile organic compounds and related microcontaminants in the Scheldt estuary and the southern North Sea: method development and monitoring. PhD Thesis. Vrije Universiteit Amsterdam: Amsterdam. 254 pp., more
Related to:
Roose, P.; Brinkman, U.A.Th. (1998). Determination of volatile organic compounds in marine biota. J. Chromatogr. 799(1-2): 233-248. https://dx.doi.org/10.1016/S0021-9673(97)01081-9, more

Available in  Authors 

Keywords
    Chemical compounds > Organic compounds > Hydrocarbons > Unsaturated hydrocarbons > Aromatic hydrocarbons > Benzene
    Chemical compounds > Organic compounds > Hydrocarbons > Unsaturated hydrocarbons > Aromatic hydrocarbons > Xylene
    Chemistry > Chemicals > Organic compounds > Aromatic compounds > Hydrocarbons > Aromatic hydrocarbons > Solvents > Toluene
    Disciplines > Chemistry > Chemicals > Organic compounds > Organic halogen compounds > Organochlorine compounds
    Fauna > Aquatic organisms > Aquatic animals > Fish
    Methylbenzene > Phenylmethane > Toluene
    Organochlorine compounds
    Toluene
    Volatile organic compounds
    Marine/Coastal

Authors  Top 
  • Roose, P., more
  • Brinkman, U.A.Th., more

Abstract
    A method was developed that allows the simultaneous determination of the volatile organochlorines (VOCs) chloroform, tetrachloromethane, 1,1-dichloroethane, 1,2-dichloroethane, 1,1,1-trichloroethane, trichloroethene and tetrachloroethene and the volatile aromatics benzene, toluene, ethylbenzene and the xylenes (BTEX) in marine biota. The biological tissue is first homogenised (at 0°C) using an ultra-turrax blender and transferred to a 25-ml EPA vial. After addition of 15 ml of water and internal standard (1,1,1-trifluorotoluene), the homogenate is treated in an ultrasonic bath (20 min at 0°C) to further disrupt the tissue. The glass vessel is then connected to a Tekmar LSC 2000 purge-and-trap apparatus coupled to a gas chromatography-mass spectrometry (GC-MS) system. The volatiles are forced out of the tissue by purging with a stream of helium gas while heating at 70°C and trapped onto a Vocarb 4000 sorbent trap. After purging, the trap is backflushed while being rapidly heated to 250°C and the analytes are desorbed and, next, trapped in a cryofocusing module (-120°C) connected to the analytical column (Restek, RTx-502.2, 60 m×0.32 mm I.D., 1.8 µm film). The analytes are injected into the column by rapidly heating the module (from -120°C to 200°C in 0.75 min). Identification and quantification were performed with mass spectrometry operated in the electron impact mode. The method allows detection limits between 0.005 ng/g (1,2-dichoroethane, 1,1-dichloroethane and tetrachloromethane) and 0.2 ng/g (chloroform) depending on the background levels and the amount of sample. The reproducibility varies between 8.4% for toluene and 36% for chloroform and the recoveries range from 63% for trichloroethene to 115% for dichloroethane. The method was used to determine the concentrations of VOCs in Limanda limanda (dab) and Merlangius merlangus (whiting) collected at two sampling stations located on the Belgian continental shelf. Liver and muscle tissue were individually analysed in order to determine the inter-species and inter-specimen variability. The results show a considerable variability within tissues of the same species (R.S.D., 50-200%). In most cases, the concentrations of the VOCs appeared to be normally distributed. Although the levels are generally low (low ng/g range), up to 572 ng/g of tetrachloromethane was detected in the liver of whiting.

All data in the Integrated Marine Information System (IMIS) is subject to the VLIZ privacy policy Top | Authors