Welkom op het expertplatform!
Dit platform verschaft informatie en kennis omtrent de WL expertisedomeinen 'hydraulica en sediment', 'havens en waterwegen', 'waterbouwkundige constructies', 'waterbeheer' en 'kustbescherming' - gaande van WL medewerkers met hun expertise, het curriculum van deze instelling, tot publicaties, projecten, data (op termijn) en evenementen waarin het WL betrokken is.
Het WL onderschrijft het belang van "open access" voor de ontsluiting van haar onderzoeksresultaten. Lees er meer over in ons openaccessbeleid.
one publication added to basket [225698] |
Application of a silicone rubber passive sampling technique for monitoring PAHs and PCBs at three Belgian coastal harbours
In: Chemosphere. Elsevier: Oxford. ISSN 0045-6535; e-ISSN 1879-1298
| |
Trefwoord |
|
Author keywords |
PAHs; PCBs; Monitoring; Passive sampling; Sampling rate; Belgian coastal zone |
Auteurs | | Top |
- Monteyne, E.
- Roose, P.
- Janssen, C.R.
|
|
|
Abstract |
A 4-year monitoring was performed to study the freely dissolved water concentrations of PAHs and PCBs in three coastal harbours and at an offshore station in the North Sea. The results are part of a more extensive study to provide information on occurrence, distribution and effects of pollutants in the Belgian coastal zone. Several methods for the estimation of freely dissolved water concentrations are reported in the literature. In the present study silicone rubber passive samplers were used. The non-linear least-square (NLS) method proved to be suitable for estimating sampling rates when using the following performance reference compounds: fluorene-d10, phenanthrene-d10, fluoranthene-d10, benzo(e)pyrene-d12, coronene-d12, CB10, CB14, CB50, CB104, CB145 and CB204. The application of two NLS methods for estimating the sampling rate (Rs) resulted in significant differences for freely dissolved concentrations for individual compounds of up to 30% between the two methods. A model that takes into account the decrease of sampling rate for compounds with higher molecular weight should give a more accurate Rs and was the preferred estimation method. Rs varied from 0.9 to 34.8 L d-1 for the different target compounds, while estimated freely dissolved concentrations for sum 15 PAHs varied between 3.9 and 170 ng L-1 and for sum 14 PCBs between 0.030 and 3.1 ng L-1. The stations located within marinas showed the highest level of contamination, while the offshore station (5 mile from coastline) exhibited the lowest level. The implications of the use of passive samplers for monitoring programs are discussed. |
IMIS is ontwikkeld en wordt gehost door het VLIZ.