Welkom op het expertplatform!
Dit platform verschaft informatie en kennis omtrent de WL expertisedomeinen 'hydraulica en sediment', 'havens en waterwegen', 'waterbouwkundige constructies', 'waterbeheer' en 'kustbescherming' - gaande van WL medewerkers met hun expertise, het curriculum van deze instelling, tot publicaties, projecten, data (op termijn) en evenementen waarin het WL betrokken is.
Het WL onderschrijft het belang van "open access" voor de ontsluiting van haar onderzoeksresultaten. Lees er meer over in ons openaccessbeleid.
[ meld een fout in dit record ] | mandje (1): toevoegen | toon |
one publication added to basket [291486] | |
Discharge measurements at bypass in Genk and Postels vaartje and watercapture 33B in Lommel: control of theoretical discharges Vereecken, H.; Claeys, S.; Deschamps, M.; Mostaert, F. (2017). Discharge measurements at bypass in Genk and Postels vaartje and watercapture 33B in Lommel: control of theoretical discharges. Version 4.0. FHR reports, 17_071_2. Flanders Hydraulics Research: Antwerp . VII, 15 + 38 p. appendices pp.
Deel van: FHR reports. Flanders Hydraulics Research: Antwerp, meer
|
Beschikbaar in | Auteurs |
| |
Documenttype: Projectrapport |
Trefwoorden |
Discharge In-situ measurements Low water Water management > Monitoring-networks > Discharges Water management > Risk > Low water strategies Water management > Water quantity > Water balance - Water availability Water management > Water quantity > Water system knowledge |
Project | Top | Auteurs |
|
Auteurs | Top | |
Abstract |
The detailed amount of flow through the bypass in Genk is measured with Rio Grande ADCP upstream at the entrance the inlet. The results of these measurements are compared with theoretical discharges used by the water managers of de Vlaamse Waterweg nv (dVW). The quantity of the flow towards "Postels Vaartje" and "water capture 33b" is measured with Streampro- ADCP. For Postels Vaartje the measurements have been executed from the bridge 80m downstream and downstream and close to the inlet. For watercapture 33b Streampro is operated from a bridge 10 m downstream of the inlet. Results of the measurement in Genk indicate that the theoretical discharges are not reached and are overestimated by 10-70 % at the tested opening diameters. Results of the measurement at Postels Vaartje show discharges from 0,19 to 0,77 m3/s at the different opening heights tested. Results of measurements of watercapture 33b show discharges of about 0,11 m3/s. Both results are comparable with discharge measurements with Qliner ADCP at the same locations in 2005. |
Top | Auteurs |