Welkom op het expertplatform!
Dit platform verschaft informatie en kennis omtrent de WL expertisedomeinen 'hydraulica en sediment', 'havens en waterwegen', 'waterbouwkundige constructies', 'waterbeheer' en 'kustbescherming' - gaande van WL medewerkers met hun expertise, het curriculum van deze instelling, tot publicaties, projecten, data (op termijn) en evenementen waarin het WL betrokken is.
Het WL onderschrijft het belang van "open access" voor de ontsluiting van haar onderzoeksresultaten. Lees er meer over in ons openaccessbeleid.
one publication added to basket [323309] |
Ocean acidification reduces spine mechanical strength in euechinoid but not in cidaroid sea urchins
Dery, A.; Collard, M.; Dubois, P. (2017). Ocean acidification reduces spine mechanical strength in euechinoid but not in cidaroid sea urchins. Environ. Sci. Technol. 51(7): 3640-3648. https://dx.doi.org/10.1021/acs.est.6b05138
In: Environmental Science and Technology. American Chemical Society: Easton. ISSN 0013-936X; e-ISSN 1520-5851
| |
Auteurs | | Top |
- Dery, A.
- Collard, M.
- Dubois, P.
|
|
|
Abstract |
Echinoderms are considered particularly sensitive to ocean acidification (OA) as their skeleton is made of high-magnesium calcite, one of the most soluble forms of calcium carbonate. Recent studies have investigated effects of OA on the skeleton of “classical” sea urchins (euechinoids), but the impact of etching on skeleton mechanical properties is almost unknown. Furthermore, the integrity of the skeleton of cidaroids has never been assessed, although their extracellular fluid is under-saturated with respect to their skeleton, and the skeleton of their primary spines is in direct contact with seawater. In this study, we compared the dissolution of test plates and spines as well as the spine mechanical properties (two-points bending tests) in a cidaroid (Eucidaris tribuloides) and a euechinoid (Tripneustes ventricosus) submitted to a 5 week acidification experiment (pHT of 8.1, 7.7, and 7.4). Test plates of both species were not affected by dissolution. The spines of E. tribuloides showed no mechanical effects at pHSW-T 7.4 despite having traces of corrosion on secondary spines. On the contrary, spines of the T. ventricosus were significantly etched at both pHSW-T 7.7 and 7.4 and their fracture force reduced by 16 to 35%, respectively. This increased brittleness is probably of little significance with regards to predation protection but has consequences in terms of energy allocation. |
IMIS is ontwikkeld en wordt gehost door het VLIZ.