Overslaan en naar de inhoud gaan
Publicaties | Personen | Instituten | Projecten
[ meld een fout in dit record ]mandje (1): toevoegen | toon Print deze pagina

one publication added to basket [289115]
Development and validation of an ultra-high performance liquid chromatographic high resolution Q-Orbitrap mass spectrometric method for the simultaneous determination of steroidal endocrine disrupting compounds in aquatic matrices
Huysman, S.; Van Meulebroek, L.; Vanryckeghem, F.; Van Langenhove, H.; Demeestere, K.; Vanhaecke, L. (2017). Development and validation of an ultra-high performance liquid chromatographic high resolution Q-Orbitrap mass spectrometric method for the simultaneous determination of steroidal endocrine disrupting compounds in aquatic matrices. Anal. Chim. Acta 984: 140-150. https://dx.doi.org/10.1016/j.aca.2017.07.001
In: Analytica Chimica Acta. Elsevier: New York; Amsterdam. ISSN 0003-2670; e-ISSN 1873-4324, meer
Peer reviewed article  

Beschikbaar in  Auteurs | Datasets 

Trefwoord
    Marien/Kust
Author keywords
    Endocrine disrupting compounds; UHPLC-HR-Q-Orbitrap-MS; Speedisks; Steroids; Water Framework Directive; Residues

Auteurs  Top | Datasets 
  • Huysman, S., meer
  • Van Meulebroek, L., meer
  • Vanryckeghem, F., meer
  • Van Langenhove, H., meer
  • Demeestere, K., meer
  • Vanhaecke, L., meer

Abstract
    The lack of adequate strategies for monitoring endocrine disrupting compounds (EDCs) in the aquatic environment is emphasized in the European Water Framework Directive. In this context, a new UHPLC-HR-Q-Orbirtrap-MS multi-residue method was developed for the simultaneous measurement of 70 steroidal EDCs in two aquatic matrices, i.e. sea and fresh water. First, an instrumental APCI-UHPLC-HR-Q-Orbitrap-MS was devised for separating and detecting the EDC isomers and mass analogues, within 12.5 min per run. Next, an appropriate extraction was statistically optimised using a three-strep workflow (95% confidence interval, p > 0.05); including fractional factorial resolution IV, simplex lattice, and response surface methodological designs. The fitness-for-purpose of the method was demonstrated through successful validation at relevant environmental concentrations, i.e. the low nano- and picogram range. Method quantification limits ranged for the androgens (n = 33), oestrogens (n = 14), progestins (n = 12), and corticosteroids (n = 11) between, respectively, 0.13 and 5.00 ng L−1, 0.25 and 5.00 ng L−1, 0.13 and 2.50 ng L−1, and 0.50 and 5.00 ng L−1. Good linearity (R2 ≥ 0.99) and no lack of fit was observed (95% confidence interval, p > 0.05) for the 70 steroidal EDCs. In addition, good recovery (95–109%) and satisfactory repeatability (RSD < 8.5%, n = 18) and reproducibility (RSD < 10.5%, n = 12) were obtained. Finally, the applicability of the multi-residue method was demonstrated by measuring steroidal EDC in 28 sea water samples collected from four different locations during fall 2016 and winter 2017. Regarding the sea water samples, all the classes were ubiquitously present and included different metabolites, transformation product and or degradation products from the parent EDCs (n = 43).

Datasets (2)
  • Huysman, S.; Vanhaecke, L.; Laboratory for Chemical Analysis (LCA). Ugent: Belgium; (2020): Advanced analysis of (emerging) organic trace contaminants in the harbours of Oostende and Zeebrugge and the Belgian coastal zone: steroidal EDC's, plasticizers and plastic additives., meer
  • Vanryckeghem, F.; Demeestere, K.; Environmental Organic Chemistry and Technology research group (EnVOC). Ugent: Belgium; (2020): Advanced analysis of (emerging) organic trace contaminants in the harbours of Oostende and Zeebrugge and the Belgian coastal zone: pesticides, pharmaceuticals and personal care products., meer

Alle informatie in het Integrated Marine Information System (IMIS) valt onder het VLIZ Privacy beleid Top | Auteurs | Datasets