Overslaan en naar de inhoud gaan
Publicaties | Personen | Instituten | Projecten
[ meld een fout in dit record ]mandje (0): toevoegen | toon Print deze pagina

Calibration and validation of a generic multisensor algorithm for mapping of turbidity in coastal waters
Nechad, B.; Ruddick, K.G.; Neukermans, G. (2009). Calibration and validation of a generic multisensor algorithm for mapping of turbidity in coastal waters, in: Bostater, C.R. et al. Remote Sensing of the Ocean, Sea Ice, and Large Water Regions 2009. Berlin, Germany, August 31, 2009. Proceedings of SPIE, the International Society for Optical Engineering, 74730: pp. 11. https://dx.doi.org/10.1117/12.830700
In: Bostater, C.R. et al. (2009). Remote Sensing of the Ocean, Sea Ice, and Large Water Regions 2009. Berlin, Germany, August 31, 2009. Proceedings of SPIE, the International Society for Optical Engineering, 74730. SPIE: Bellingham. ISBN 9780819477781. , meer
In: Proceedings of SPIE, the International Society for Optical Engineering. SPIE: Bellingham, WA. ISSN 0277-786X; e-ISSN 1996-756X, meer
Peer reviewed article  

Beschikbaar in  Auteurs 
Documenttype: Congresbijdrage

Trefwoord
    Marien/Kust

Project Top | Auteurs 
  • BELCOLOUR-2 : Optical remote sensing of marine, coastal and inland waters, meer

Auteurs  Top 

Abstract
    Turbidity, as defined in the standard ISO7027, is a parameter that is routinely measured in many national and regional water quality monitoring programmes. The definition of turbidity according to ISO and as related to satellite data products is discussed. While satellite data products are beginning to become available for the closely related parameter, Total Suspended Matter (TSM), the direct estimation of turbidity as a satellite data product has not yet been addressed. In situ measurements of TSM and of turbidity, obtained in the Southern North Sea (SNS), show high correlation (correlation coefficient of 98.6%). A generic multisensor algorithm for TSM as function of reflectance has been previously developed. The methodology is extended here to the estimation of turbidity from water-leaving reflectance. A set of 49 seaborne measurements of reflectance in the spectral range 600-850nm and turbidity in the SNS are used to calibrate the algorithm. The algorithm is also calibrated for the specific bands of MERIS. Validation of these models is carried out using an independent set of seaborne measurements of turbidity and reflectance and shows low relative errors in turbidity retrieval at 681nm (less than 35%). This wavelength is recommended, provided no significant fluorescence affects this range.

Alle informatie in het Integrated Marine Information System (IMIS) valt onder het VLIZ Privacy beleid Top | Auteurs