Overslaan en naar de inhoud gaan
Publicaties | Personen | Instituten | Projecten
[ meld een fout in dit record ]mandje (0): toevoegen | toon Print deze pagina

Comparison of insulation provided by dry or wetsuits among recreational divers during cold water immersion (< 5°C)
Lafère, P.; Guerrero, F.; Germonpré, P.; Balestra, C. (2021). Comparison of insulation provided by dry or wetsuits among recreational divers during cold water immersion (< 5°C). Int. Marit. Health 72(3): 217-222. https://dx.doi.org/10.5603/imh.2021.0040
In: International Maritime Health. Interfaculty Institute of Maritime and Tropical Medicine in Gdynia: Gdansk. ISSN 0324-8542; e-ISSN 2081-3252, meer

Beschikbaar in  Auteurs 

Trefwoord
    Marien/Kust
Author keywords
    diving, cold water immersion, body insulation, wetsuits, dry suit, thermal imaging

Auteurs  Top 
  • Lafère, P., meer
  • Guerrero, F.
  • Germonpré, P., meer
  • Balestra, C., meer

Abstract
    Background: Divers thermal status influences susceptibility to decompression sickness hence the need for proper insulation during immersion in cold water. However, there is a lack of data on thermal protection provided by diving suits, hence this study.
    Materials and methods: Two different groups of divers wearing either a wetsuit (n = 15) or a dry suit (n = 15) volunteered for this study. Anthropometric data and dive experience were recorded; skin temperatures at the cervical-supraclavicular (C-SC) area and hands were assessed through high-resolution thermal infrared imaging taken pre- and post-dive.
    Results: As far as anthropometrics, pre-dive C-SC temperatures (37.0 ± 0.4°C), depth (dry: 43 ± 4.6 mfw vs. wet: 40.3 ± 4.0 mfw) and water temperature exposure (4.3°C) are concerned, both groups were comparable. Total dive time was slightly longer for dry suit divers (39.6 ± 4.0 min vs. 36.5 ± 4.1 min, p = 0.049). Post-dive, C-SC temperature was increased in dry suit divers by 0.6 ± 0.6°C, and significantly decreased in wetsuit divers by 0.8 ± 0.6°C. The difference between groups was highly significant (dry: 37.5 ± 0.7°C vs. wet: 36.2 ± 0.7°C, p = 0.004). Hand’s temperature decreased significantly in both groups (dry: 30.3 ± 1.2°C vs. wet: 29.8 ± 0.8°C, p = 0.33). Difference between groups was not significant.
    Conclusions: Medium-duration immersion in cold water (< 5°C), of healthy and fully protected subjects was well tolerated. It was demonstrated that proper insulation based on a three-layer strategy allows maintaining or even slightly improve thermal balance. However, from an operational point of view, skin extremities are not preserved.

Alle informatie in het Integrated Marine Information System (IMIS) valt onder het VLIZ Privacy beleid Top | Auteurs